FEATURES |
VALUES/ STANDARDS |
Starting |
Star Delta |
Permissible starts/hr |
Cold successive - 4 , Hot successive; - 3 , Equally spread - 6 |
Loading at reduced volts |
75% Rated volts for 5 minutes |
Insulation / temp.rise |
Class `F' / 70°C |
Direction of rotation |
Bi-directional |
No. Of leads |
6 |
Connection |
Delta for all frames |
Degree of protection |
IP 22 for SA/VSA series up to 225 Frames, IP 23 for SA/VSA series - 250 to 355 Frames |
Method of cooling |
IC 01 |
T.box position |
RHS looking from DE. |
Bearing life
(90% survival basis) |
40,000 working hrs. For direct drive
20,000 working hrs. For belt drive |
Vibration |
Normal class as per is 12075 |
Noise |
As per IS 12065 |
Construction |
Foot mounted / 'B' flange mounted |
Frame sizes |
SA / VSA 180 to 355. (for 'B' flange mounting ratings covered in SA180M to be offered in VSA180L, & ratings covered in SA200M to be offered in VSA200L) |
Shaft extension |
Single cylindrical extension as per IS 1231 |
Body material |
Cast iron |
T.box material |
Cast iron up to 225 frames, mild steel for 250 to 355 Frames |
Fan material |
Aluminium for all 2 pole ratings of SA frame & all ratings of VSA frame, Propylene for 4, 6, & 8 pole ratings of SA180 to 225 frame, mild steel for 250 to 355 – 2pole, Mild steel / Aluminium for 250 to 355 frames – 4, 6, and 8 poles. |
Accessories
|
Nil. |
Paint & shade |
NC base RAL5012 shade up to 225, Epoxy base RAL5012 above 225 |
Bearing type
Greasing facility |
Open type ball/roller bearings
Online greasing facility for all |